<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-27 14-48-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 51 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 69 kHz 12991 3,8411
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,5 dBr 4,23 dBr 5,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 69 kHz MIN: 12 kHz % above 76 kHz: 3,8411 Acquired: 2025/07/27 14.47.17 Total samples: 12991 Equivalent time: 0:10:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,6 dBr MIN: 3,5 dBr AVE: 4,23 dBr % above 12,2 dBr: 0,0 Last value: 5,3 dBr (2025/07/27 14.47.17) 14.34 14.36 14.38 14.40 14.42 14.44 14.46 0 2 4 6 Pm [dBr]